A graph-drawing machine
A voltmeter gives you one number. But many signals change hundreds or thousands of times a second: the output of a microphone, the a.c. mains, a heartbeat picked up by electrodes. To see how such a voltage changes with time you need an instrument that draws its graph live. That instrument is the cathode ray oscilloscope (CRO). Modern digital oscilloscopes use a screen and a computer chip, but the classic CRO does the whole job with one beam of electrons.
The cathode ray tube
The heart of a CRO is a cathode ray tube (CRT): an evacuated glass tube with three main parts.
1. The electron gun
- A small filament (F), heated by a low-voltage supply, warms the cathode (C), and the hot cathode gives off electrons.
- In front of the cathode is a control grid (G), held negative. It repels some of the electrons, so it decides how many get through. More electrons make a brighter spot, so the grid is the brightness control.
- A set of anodes at a high positive potential pulls the electrons forward at great speed and squeezes them into a narrow, focused beam.
2. The deflecting system
The beam then passes between two pairs of metal plates. A voltage across a pair bends the beam towards whichever plate is positive (see deflection of electron beams).
- The Y-plates are horizontal, one above the other, and move the beam up and down. The signal you want to study goes here.
- The X-plates are vertical, side by side, and move the beam left and right. The time base goes here.
3. The fluorescent screen
The inside of the wide end of the tube is coated with a fluorescent material that glows where the electrons strike. The beam makes a bright spot; as the spot moves, it leaves a glowing line, the trace.
The time base: a saw-tooth voltage
To draw a graph against time, the spot must move across the screen at a steady speed, then jump back and start again. The CRO does this by putting a saw-tooth voltage on the X-plates:
- The voltage rises steadily (a straight slope), so the spot glides from left to right at a constant rate. Equal distances across the screen now stand for equal intervals of time.
- The voltage then falls almost instantly to its starting value, flicking the spot back to the left edge.
- The pattern repeats, sweep after sweep.
Drawn on a graph, this voltage looks like the teeth of a saw: a long, gentle slope followed by a near-vertical drop.
Drawing the waveform
With the time base sweeping the spot across and a signal on the Y-plates pushing it up and down at the same time, the spot traces out voltage against time. A sine-wave signal draws a sine wave; a square-wave signal draws a square wave; a saw-tooth signal draws saw teeth.
Keeping the picture still. Each new sweep must start at the same point of the signal, so that every trace lands on top of the last. This happens when a whole number of the signal's cycles fits into one sweep, that is, when the signal's frequency is the same as the time-base frequency or a whole-number multiple of it. A CRO has controls for matching the two. Otherwise the waveform drifts across the screen.
What a CRO can measure
The screen is ruled into a grid of squares called divisions. Two controls tell you what one division is worth:
- the time base setting, e.g. 5 ms/div, for each division across;
- the Y-gain (volts per division), e.g. 2 V/div, for each division up.
From a trace you can find:
- the peak voltage (amplitude): measure how many divisions a peak stands above the centre line and multiply that number by the Y-gain;
- the time period : count the divisions for one complete cycle, then multiply by the time base;
- the frequency: , with in seconds;
- a phase difference: show two signals together. If one is at its peak whenever the other is at its trough, they are 180° out of phase.
CROs are used to test electronic circuits, to display sound waves picked up by a microphone (as in characteristics of sound), and in hospitals, where similar displays show a patient's heartbeat (ECG).
Worked numerical 1: reading a sine-wave trace
One full cycle of a trace spans 2.5 divisions across. Its peaks are 3.5 divisions above the centre line. The time base is 10 ms/div and the Y-gain is 2 V/div.
Period:
Frequency:
Peak voltage:
Measured trough-to-peak, the trace is twice this height, 14 V (the peak-to-peak value).
Worked numerical 2: choosing the sweep
A 150 Hz signal is to be shown with exactly three complete cycles on the screen, which is 10 divisions wide.
Three cycles take s, so each sweep must last 0.020 s (a 50 Hz time base). Spread over 10 divisions:
Worked numerical 3: a battery on the Y-plates
A battery is connected to the Y-input with the time base running. The trace becomes a flat line 2.4 divisions above the centre. The Y-gain is 5 V/div.
A steady d.c. voltage gives a straight horizontal line, because the spot is held at the same height throughout every sweep.
Traces in the simulation
- Choose AC supply and turn on Measuring marks. Read the One cycle and Period cards, then check Frequency with f = 1/T.
- Change Time/div. The wave squashes or stretches across the screen, yet the Frequency card does not change: the time base only changes the drawing.
- Change Volts/div and watch the height of the trace change while the Peak voltage card stays the same.
- Choose Both. The battery's flat line never crosses 0 V; the a.c. wave crosses it twice in every cycle.