Turning motion into electricity
An a.c. generator (also called an alternator) changes kinetic energy of rotation into electrical energy by electromagnetic induction. The turning can come from steam, falling water, wind or a diesel engine, but the electrical part is the same: a coil and a magnetic field moving relative to each other, so the flux through the coil keeps changing.
The parts of a simple generator
- Coil (armature): a flat rectangular loop wound from many turns of insulated copper, fixed to an axle that is turned from outside.
- Magnet: a strong magnet whose N and S poles face each other across the coil, so a field crosses the gap.
- Slip rings: two separate metal rings fixed to the axle. Each ring is connected to one end of the coil, and both rings turn with it.
- Carbon brushes: two fixed blocks of carbon pressed against the rings by springs. They slide on the turning rings and carry the current out to the external circuit.
Without slip rings the wires from the coil would twist up after a few turns. The rings and brushes keep the spinning coil connected to a circuit that stays still. Because each end of the coil always touches the same brush, every reversal of the e.m.f. in the coil also reaches the external circuit, so the output is alternating.
How the e.m.f. is produced
As the coil turns, its two long sides move through the magnetic field. While they cut across field lines, each side has an e.m.f. induced in it. The two sides move in opposite directions, one up and one down, so their e.m.f.s point the same way round the coil and add together.
How big the e.m.f. is at any moment depends on how fast the sides are cutting field lines:
- When the coil's face is square-on to the field (its plane at 90° to the field: vertical in the usual diagram, with the poles to the left and right), for a moment the long sides travel parallel to the field lines. They cut no lines, so the e.m.f. is zero. (This is also when the most flux passes through the coil, but it is not changing at that instant.)
- When the coil is edge-on to the field (horizontal in the usual diagram), the sides slice directly across the lines at the greatest rate. The e.m.f. is at its maximum.
After half a turn, each side has swapped places: the side that was moving up is now moving down. The e.m.f. therefore reverses every half turn.
The e.m.f.–time graph
Starting with the coil vertical, one complete turn gives one complete cycle of a sine wave:
| Angle turned | Coil position | e.m.f. |
|---|---|---|
| 0° (0 rad) | vertical | zero |
| 90° (π/2 rad) | horizontal | positive maximum (peak) |
| 180° (π rad) | vertical | zero |
| 270° (3π/2 rad) | horizontal | negative maximum (trough) |
| 360° (2π rad) | vertical again | zero, and the cycle repeats |
Frequency counts how many full cycles happen in one second, measured in hertz (Hz). For a simple two-pole generator each turn makes one cycle, so the frequency in hertz is just the turning rate in turns per second. Mains electricity in Pakistan is 50 Hz: the coil of a simple generator would have to turn 50 times a second, which is 3000 turns a minute.
Changing the output
| Change | Peak e.m.f. | Frequency |
|---|---|---|
| Turn the coil faster | larger | higher |
| Use more turns on the coil | larger | no change |
| Use a stronger magnet | larger | no change |
| Use a coil of bigger area | larger | no change |
Only the turning speed changes the frequency, because only it changes how many cycles happen each second. Each of the four changes makes the coil cut field lines faster, so each one raises the peak.
Rotating coil or rotating magnet
In the classroom generator the coil turns inside a fixed magnet. Large power-station generators do the opposite: an electromagnet spins inside fixed coils wound round the inside of the casing. The big output current then flows straight out of the fixed coils without passing through any sliding contact. Where slip rings and brushes are still used, they carry only the small current that feeds the spinning electromagnet. A bicycle dynamo that rubs on the tyre also spins a magnet inside a fixed coil, and needs no slip rings at all.
Worked numerical 1: from turning rate to frequency
A generator coil turns at 1500 turns per minute. Find the frequency of its output and the time for one cycle.
Worked numerical 2: reading the graph
A coil turns 20 times a second, starting from the vertical position at . At what times during the first turn is the e.m.f. (a) zero, (b) at its positive peak, (c) at its negative peak?
One turn takes , so each quarter turn takes .
(a) Zero when vertical: , and .
(b) Positive peak at a quarter turn: .
(c) Negative peak, three quarters of the way round: .
Worked numerical 3: reversals each second
A 50 Hz supply goes through 50 complete cycles a second. How many times a second does the current change direction?
The current reverses twice in every cycle (once each half turn), so
Worked numerical 4: the peak e.m.f. (beyond the book)
A coil of 100 turns and area 0.010 m² spins 50 times a second in a 0.20 T field. Find its peak e.m.f.
The generator in the 3D simulation
Keep Slip rings selected and press Play.
- Keep an eye on two cards at once, Coil’s plane and Output e.m.f. now. When the first one reads At right angles to the field, the output passes through zero; when it lies Along the field, the graph reaches a peak or trough.
- Double the Turning speed. The Peak e.m.f. and the Frequency both double, and the cycles on the graph squeeze closer together.
- Raise the Turns on the coil or the Field between the poles instead. The peak grows, but the Frequency stays the same.
- Use the Front, Side and Top camera views to follow one side of the coil round, and turn on Direction each side of the coil moves to see when it cuts across the lines.