Aim
To show that moving a magnet near a coil, or moving a wire through a magnetic field, induces an e.m.f., to find what reverses it, and to find what makes it bigger.
Equipment
- a coil of insulated copper wire (the lab's has 200 turns), and coils with fewer and more turns
- a sensitive centre-zero meter (a galvanometer) and two connecting leads
- a bar magnet, plus a weaker and a stronger magnet
- for part 3: a U-shaped magnet and a length of bare or insulated copper wire
- optional: a data logger or an oscilloscope to record the e.m.f. against time
There is no cell or power supply anywhere in the circuit.
Variables
| Type | In this practical |
|---|---|
| Independent | Part 1: the movement (in, out or held still) and the pole facing the coil. Part 2: one at a time, the speed of the push, the number of turns, the strength of the magnet. Part 3: the direction the wire moves |
| Dependent | The furthest point of the needle's swing: which way it goes (+ or −) and how far |
| Control | The same meter and range, the needle on 0 before starting, the magnet pushed all the way to the middle of the coil, and in part 2 the two factors not being tested |
Part 1 is about direction, so one reading of each movement is enough. Part 2 compares sizes, so it uses three pushes at each setting.
Method
- Join the two ends of the coil to the meter. With nothing moving, check that the needle rests on 0; if it does not, turn the adjusting screw until it does.
- Push the N pole of the bar magnet into the coil at a steady speed. Note which way the needle swings and the furthest point it reaches, then watch it come back.
- Hold the magnet still inside the coil and read the meter. Then pull the magnet out and note the swing.
- Turn the magnet round and repeat steps 2 and 3 with the S pole facing the coil.
- Go back to the N pole. Push it in three times at the standard set-up, then change one thing at a time: a slower and a faster push, a coil with fewer and with more turns, a weaker and a stronger magnet. Push three times at each setting and find the mean.
- Optional: hold a straight wire, joined to the meter, through the gap of a U-shaped magnet. Move it down through the gap, then up, then sideways from one pole towards the other, and hold it still. Note the meter each time.
In the virtual lab above, Push in, Pull out and Hold still do steps 2 and 3, and Pole facing the coil does step 4. Set the needle to zero first starts switched on: switch it off to see what a zero error does. The trace under the bench is what a data logger would record.
Risk assessment
| Hazard | Risk | Control |
|---|---|---|
| Magnets close to phones and cards | Stored data or the device damaged | Keep magnets at a distance from electronics |
| Two magnets clashing | Trapped skin; chipped magnets | Move one magnet at a time and keep them apart, with keepers, when stored |
| A magnet dropped through a vertical coil | A chipped magnet or a bruised foot | Catch it on a soft pad |
The circuit contains no cell or mains supply, so there is no electrical hazard.
Analysing the results
- Direction. Compare the signs. A + reading and a − reading of about the same size mean the e.m.f. was reversed.
- No change, no e.m.f. A magnet held still gives a reading of 0, however strong it is and even when it is inside the coil.
- Size. For each factor, line up the means for the three settings and see whether they rise. Only compare rows that differ from the standard set-up in one thing.
- Uncertainty. Use half the range of the repeats (never less than half a reading step, 0.25 mV here). Leave an anomalous reading out of the mean and say why.
A still magnet that seems to give a reading means the needle was not on 0 to start with. That zero error moves every reading by an equal amount: take it off each one before you compare them.
Typical results
Part 1, from the virtual lab with the needle set to zero first:
| Pole facing the coil | Movement | Furthest point of the swing / mV |
|---|---|---|
| N | pushed in | +4.0 |
| N | pulled out | −4.0 |
| N | held still inside | 0.0 |
| S | pushed in | −4.0 |
| S | pulled out | +4.0 |
The same five movements with the needle left resting at +1.0 mV gave +5.0, −3.0, +1.0, −3.0 and +5.0 mV. The push and the pull no longer match in size, and the still magnet seems to give a reading: both give away the zero error.
Part 2, three pushes of the N pole at each setting:
| Setting | Push 1 / mV | Push 2 / mV | Push 3 / mV | Mean / mV |
|---|---|---|---|---|
| slow, 200 turns, standard magnet | 2.0 | 2.0 | 2.0 | 2.0 ± 0.3 |
| medium, 200 turns, standard magnet | 4.0 | 4.0 | 3.5 | 3.8 ± 0.3 |
| fast, 200 turns, standard magnet | 8.5 | (4.5) | 8.5 | 8.5 ± 0.3 |
| medium, 100 turns, standard magnet | 1.5 | 2.0 | 2.0 | 1.8 ± 0.3 |
| medium, 400 turns, standard magnet | 8.0 | 7.5 | 8.5 | 8.0 ± 0.5 |
| medium, 200 turns, weak magnet | 2.0 | 2.0 | 2.0 | 2.0 ± 0.3 |
| medium, 200 turns, strong magnet | 8.5 | 8.0 | 9.0 | 8.5 ± 0.5 |
The 4.5 mV reading is far below the other two fast pushes and is left out of the mean. That push was hesitant: the magnet went in at about half the speed intended.
All three factors make a difference. Four times the speed raised the mean from 2.0 mV to 8.5 mV; four times as many turns raised it from 1.8 mV to 8.0 mV; and the strong magnet (four times as strong as the weak one in the model) gave 8.5 mV against 2.0 mV.
Part 3, the wire: down +1.0 mV, up −1.1 mV, sideways 0.0 mV and held still 0.0 mV, on the ±2 mV range.
Evaluation
Zero error. Always look at the needle before you start, with nothing moving, and set it to 0. Otherwise every reading is shifted the same way, and a still magnet seems to induce an e.m.f.
Hand speed. A hand never moves at exactly the same speed twice, so the readings scatter by a few per cent, and now and then a push is far slower than meant. Repeats show this up. Dropping the magnet through a vertical coil from the same height gives a far more repeatable speed.
Reading a moving needle. The needle swings out and straight back, so its furthest point can only be judged to about half a division. A data logger or an oscilloscope records the whole pulse instead.
The meter. The e.m.f. is only a few millivolts, too small for an ordinary school voltmeter or ammeter. A centre-zero meter swings both ways, so it shows the direction as well as the size.
One factor at a time. The standard row belongs to all three comparisons, so a slip in it affects every one. Repeat it with extra care.
How the practical is examined
Exam-style questions
1. Describe an experiment to show that an e.m.f. can be induced by a moving magnet. Include what you would see. (4 marks)
2. A student's meter gives +5.0 mV when a magnet is pushed in, −3.0 mV when it is pulled out at the same speed, and +1.0 mV when it is held still. Explain what is wrong and give the corrected readings. (3 marks)
3. Three pushes at the same setting give 8.5 mV, 4.5 mV and 8.5 mV. Which reading is anomalous? Suggest what caused it and say how to treat it. (3 marks)
4. (Supplement) A straight wire runs into the page between the poles of a magnet, with the field pointing from left to right across the page. The wire is part of a complete circuit and is moved downwards. State the direction of the induced current, and what happens to it when the wire is moved to the right instead. (2 marks)