Skip to content

Virtual practical· AQA RP 3

Electrolysis Required Practical (AQA GCSE Chemistry) with Virtual Lab

Pass a current through salt solutions using inert carbon electrodes, identify the product at each electrode with simple tests, and check your hypothesis against the rules for aqueous electrolysis. The 3D cell lets you try every solution before your lesson.

GCSE AQA Chemistry: Required practical 3Cambridge IGCSE Chemistry: Practical assessment context (Papers 5 and 6)
Loading simulation…

Pass a current through salt solutions using inert carbon electrodes, identify the product at each electrode with simple tests, and check your hypothesis against the rules for aqueous electrolysis. The 3D cell lets you try every solution before your lesson.

GCSE AQA Chemistry: Required practical 3Cambridge IGCSE Chemistry: Practical assessment context (Papers 5 and 6)

In short

What happens in the electrolysis required practical?

You put two carbon electrodes into a salt solution, connect them to a low-voltage DC supply and watch each electrode. With copper(II) chloride, a pink-brown copper coating forms on the negative electrode and chlorine bubbles off the positive one. With sodium chloride, hydrogen forms at the negative electrode instead, because sodium is more reactive than hydrogen, and chlorine still forms at the positive electrode.

Aim

To find out which products form at each electrode when solutions of ionic compounds are electrolysed with inert (carbon) electrodes, and to test a hypothesis about what decides them.

The virtual lab above is the full 3D electrolysis cell. Choose Copper(II) chloride solution or Sodium chloride solution from the electrolyte menu, press Play and follow the ions as they drift towards the electrodes and see what forms there. Then try copper(II) sulfate solution and dilute sulfuric acid to test your rule on solutions without a halide.

Apparatus

  • copper(II) chloride solution and sodium chloride solution (about 0.5 mol/dm³ is typical)
  • a 100 cm³ beaker, with a lid that has two holes to hold the electrodes apart
  • two carbon (graphite) rod electrodes
  • a low-voltage DC power supply and two leads with crocodile clips
  • blue litmus paper, dipped in water just before use, and forceps
  • a wooden splint and a Bunsen burner or other flame, for the hydrogen test
  • eye protection

Hypothesis

Before you switch on, write down what you expect at each electrode and why. A good hypothesis uses the reactivity series:

  • at the negative electrode (cathode), the metal forms if it is less reactive than hydrogen; otherwise hydrogen gas forms;
  • at the positive electrode (anode), a halogen forms if the solution contains chloride, bromide or iodide ions; otherwise oxygen forms.

So you would predict copper and chlorine for copper(II) chloride, and hydrogen and chlorine for sodium chloride.

Variables

TypeVariable
IndependentThe solution being electrolysed (which positive and negative ions it contains)
DependentThe product at each electrode, identified by what you see and by gas tests
ControlElectrode material (carbon), voltage, time switched on, concentration and volume of the solution

Method

  1. Half-fill the beaker with copper(II) chloride solution (roughly 50 cm³).
  2. Push the two carbon rods through the holes in the lid and lower them into the solution. Check that they cannot touch each other.
  3. Clip one lead to each rod and connect them to the DC terminals of the power supply. Note which rod is joined to the positive terminal.
  4. Set the supply to about 4 V and switch on. Watch both rods closely and write down what you see straight away and after a minute or two.
  5. Hold a piece of damp blue litmus paper with the forceps in the solution or the gas just next to the positive rod. Note any change of colour.
  6. After no more than about five minutes, switch off. Lift out the negative rod and look at its surface.
  7. Rinse the beaker and use clean rods. Repeat steps 1 to 6 with sodium chloride solution.
  8. For sodium chloride, the gas at the negative rod can be collected in a small test tube filled with the solution and held upside down over the rod. Hold a lighted splint at its mouth.

Results table

SolutionAt the positive electrode (anode)ProductAt the negative electrode (cathode)Product
Copper(II) chlorideBubbles; damp blue litmus turns red, then is bleached whiteChlorine, Cl₂(g)Pink-brown solid builds up on the rod; no bubblesCopper, Cu(s)
Sodium chlorideBubbles; damp blue litmus turns red, then is bleached whiteChlorine, Cl₂(g)Steady stream of bubbles; the gas burns with a squeaky popHydrogen, H₂(g)

Processing the results

This practical is mostly about observations, so processing means explaining them with the ions present. Every aqueous solution contains the ions of the salt plus a small amount of H⁺ and OH⁻ ions from water. At each electrode, only one kind of ion gains or loses electrons.

Worked example 1: predicting the products. Use the two rules from the hypothesis.

SolutionIons presentCathode (−)Anode (+)
Copper(II) chlorideCu²⁺, Cl⁻, H⁺, OH⁻Copper (copper is below hydrogen)Chlorine (halide present)
Sodium chlorideNa⁺, Cl⁻, H⁺, OH⁻Hydrogen (sodium is above hydrogen)Chlorine (halide present)
Copper(II) sulfateCu²⁺, SO₄²⁻, H⁺, OH⁻CopperOxygen (no halide)
Potassium bromideK⁺, Br⁻, H⁺, OH⁻HydrogenBromine

After electrolysing sodium chloride solution, the Na⁺ and OH⁻ ions stay behind, so the solution turns alkaline: it contains sodium hydroxide. A drop of the solution taken from beside the negative rod turns red litmus blue.

Worked example 2: comparing gas volumes. A student electrolyses dilute sulfuric acid and collects the gases in two upturned measuring tubes. After five minutes the tube over the negative electrode holds 18.6 cm³ of gas and the tube over the positive electrode holds 9.1 cm³. The ratio is 18.6÷9.1=2.0418.6 \div 9.1 = 2.04, very close to 2 : 1. This matches the half equations: 4H⁺ + 4e⁻ → 2H₂ and 4OH⁻ → O₂ + 2H₂O + 4e⁻. Every four electrons transferred release two H₂ molecules at one electrode and a single O₂ molecule at the other. (Writing half equations is for Higher tier.)

Risk assessment

HazardRiskControl
Chlorine gas made at the anodeToxic; irritates the lungs and eyes, especially for people with asthmaKeep the voltage low, switch off after a few minutes, work in a well-ventilated room and never sniff the gas directly
Copper(II) chloride solutionHarmful if swallowed; irritates eyes and skinWear eye protection, wash off any splashes and dispose of copper solutions as your teacher directs, not down the sink
Hydrogen gas tested with a flameA small, loud pop; burns from the splintTest only a small tube of gas and keep the flame away from the supply leads and your face
Electrodes touchingShort circuit; the leads and rods get hotHold the rods apart in a lid with two holes; switch off before you move them

Common errors and improvements

  • The rods touch or the gap varies. A fixed lid keeps them apart and gives the same conditions each run.
  • Dry litmus paper. Chlorine only bleaches litmus that is damp, so wet it just before you test.
  • Testing too late. Bubbles of chlorine dissolve and drift away. Test right next to the anode while the current is on.
  • Confusing the electrodes. Mark the positive lead before you start, so you know which rod is which.
  • Running too long. Chlorine builds up in the room. A few minutes is plenty to see the products.
  • Copper coating is hard to see. Start with clean, dry rods and compare the cathode with the anode after you switch off; the thin pink-brown layer shows up best side by side.
  • Improvement: collect the gases in small upturned tubes so each one can be tested properly and the volumes compared.

How this practical is examined

Exam-style questions

1. Two solutions, copper(II) chloride and sodium chloride, are to be electrolysed with inert electrodes. Plan an investigation to find what forms at each electrode, including how each product is identified. (6 marks)

2. Explain why hydrogen, not sodium, forms at the negative electrode when sodium chloride solution is electrolysed. (2 marks)

3. A student electrolyses copper(II) sulfate solution with carbon electrodes. Name the product at each electrode. (2 marks)

In your course

The same idea in your syllabus, with its own words, symbols and exam questions.

Next step

Now explore electrolysis in 3d (molten and aqueous compounds, products at each electrode) freely

The full simulation lets you change any setting and see what happens, beyond what the practical allows.