Aim
To find out which products form at each electrode when solutions of ionic compounds are electrolysed with inert (carbon) electrodes, and to test a hypothesis about what decides them.
The virtual lab above is the full 3D electrolysis cell. Choose Copper(II) chloride solution or Sodium chloride solution from the electrolyte menu, press Play and follow the ions as they drift towards the electrodes and see what forms there. Then try copper(II) sulfate solution and dilute sulfuric acid to test your rule on solutions without a halide.
Apparatus
- copper(II) chloride solution and sodium chloride solution (about 0.5 mol/dm³ is typical)
- a 100 cm³ beaker, with a lid that has two holes to hold the electrodes apart
- two carbon (graphite) rod electrodes
- a low-voltage DC power supply and two leads with crocodile clips
- blue litmus paper, dipped in water just before use, and forceps
- a wooden splint and a Bunsen burner or other flame, for the hydrogen test
- eye protection
Hypothesis
Before you switch on, write down what you expect at each electrode and why. A good hypothesis uses the reactivity series:
- at the negative electrode (cathode), the metal forms if it is less reactive than hydrogen; otherwise hydrogen gas forms;
- at the positive electrode (anode), a halogen forms if the solution contains chloride, bromide or iodide ions; otherwise oxygen forms.
So you would predict copper and chlorine for copper(II) chloride, and hydrogen and chlorine for sodium chloride.
Variables
| Type | Variable |
|---|---|
| Independent | The solution being electrolysed (which positive and negative ions it contains) |
| Dependent | The product at each electrode, identified by what you see and by gas tests |
| Control | Electrode material (carbon), voltage, time switched on, concentration and volume of the solution |
Method
- Half-fill the beaker with copper(II) chloride solution (roughly 50 cm³).
- Push the two carbon rods through the holes in the lid and lower them into the solution. Check that they cannot touch each other.
- Clip one lead to each rod and connect them to the DC terminals of the power supply. Note which rod is joined to the positive terminal.
- Set the supply to about 4 V and switch on. Watch both rods closely and write down what you see straight away and after a minute or two.
- Hold a piece of damp blue litmus paper with the forceps in the solution or the gas just next to the positive rod. Note any change of colour.
- After no more than about five minutes, switch off. Lift out the negative rod and look at its surface.
- Rinse the beaker and use clean rods. Repeat steps 1 to 6 with sodium chloride solution.
- For sodium chloride, the gas at the negative rod can be collected in a small test tube filled with the solution and held upside down over the rod. Hold a lighted splint at its mouth.
Results table
| Solution | At the positive electrode (anode) | Product | At the negative electrode (cathode) | Product |
|---|---|---|---|---|
| Copper(II) chloride | Bubbles; damp blue litmus turns red, then is bleached white | Chlorine, Cl₂(g) | Pink-brown solid builds up on the rod; no bubbles | Copper, Cu(s) |
| Sodium chloride | Bubbles; damp blue litmus turns red, then is bleached white | Chlorine, Cl₂(g) | Steady stream of bubbles; the gas burns with a squeaky pop | Hydrogen, H₂(g) |
Processing the results
This practical is mostly about observations, so processing means explaining them with the ions present. Every aqueous solution contains the ions of the salt plus a small amount of H⁺ and OH⁻ ions from water. At each electrode, only one kind of ion gains or loses electrons.
Worked example 1: predicting the products. Use the two rules from the hypothesis.
| Solution | Ions present | Cathode (−) | Anode (+) |
|---|---|---|---|
| Copper(II) chloride | Cu²⁺, Cl⁻, H⁺, OH⁻ | Copper (copper is below hydrogen) | Chlorine (halide present) |
| Sodium chloride | Na⁺, Cl⁻, H⁺, OH⁻ | Hydrogen (sodium is above hydrogen) | Chlorine (halide present) |
| Copper(II) sulfate | Cu²⁺, SO₄²⁻, H⁺, OH⁻ | Copper | Oxygen (no halide) |
| Potassium bromide | K⁺, Br⁻, H⁺, OH⁻ | Hydrogen | Bromine |
After electrolysing sodium chloride solution, the Na⁺ and OH⁻ ions stay behind, so the solution turns alkaline: it contains sodium hydroxide. A drop of the solution taken from beside the negative rod turns red litmus blue.
Worked example 2: comparing gas volumes. A student electrolyses dilute sulfuric acid and collects the gases in two upturned measuring tubes. After five minutes the tube over the negative electrode holds 18.6 cm³ of gas and the tube over the positive electrode holds 9.1 cm³. The ratio is , very close to 2 : 1. This matches the half equations: 4H⁺ + 4e⁻ → 2H₂ and 4OH⁻ → O₂ + 2H₂O + 4e⁻. Every four electrons transferred release two H₂ molecules at one electrode and a single O₂ molecule at the other. (Writing half equations is for Higher tier.)
Risk assessment
| Hazard | Risk | Control |
|---|---|---|
| Chlorine gas made at the anode | Toxic; irritates the lungs and eyes, especially for people with asthma | Keep the voltage low, switch off after a few minutes, work in a well-ventilated room and never sniff the gas directly |
| Copper(II) chloride solution | Harmful if swallowed; irritates eyes and skin | Wear eye protection, wash off any splashes and dispose of copper solutions as your teacher directs, not down the sink |
| Hydrogen gas tested with a flame | A small, loud pop; burns from the splint | Test only a small tube of gas and keep the flame away from the supply leads and your face |
| Electrodes touching | Short circuit; the leads and rods get hot | Hold the rods apart in a lid with two holes; switch off before you move them |
Common errors and improvements
- The rods touch or the gap varies. A fixed lid keeps them apart and gives the same conditions each run.
- Dry litmus paper. Chlorine only bleaches litmus that is damp, so wet it just before you test.
- Testing too late. Bubbles of chlorine dissolve and drift away. Test right next to the anode while the current is on.
- Confusing the electrodes. Mark the positive lead before you start, so you know which rod is which.
- Running too long. Chlorine builds up in the room. A few minutes is plenty to see the products.
- Copper coating is hard to see. Start with clean, dry rods and compare the cathode with the anode after you switch off; the thin pink-brown layer shows up best side by side.
- Improvement: collect the gases in small upturned tubes so each one can be tested properly and the volumes compared.
How this practical is examined
Exam-style questions
1. Two solutions, copper(II) chloride and sodium chloride, are to be electrolysed with inert electrodes. Plan an investigation to find what forms at each electrode, including how each product is identified. (6 marks)
2. Explain why hydrogen, not sodium, forms at the negative electrode when sodium chloride solution is electrolysed. (2 marks)
3. A student electrolyses copper(II) sulfate solution with carbon electrodes. Name the product at each electrode. (2 marks)