Aim
To find out how the type of surface affects how much infrared radiation it emits, and how quickly it absorbs infrared.
Equipment
- Leslie cube with a lid: a hollow metal box, each of its four sides finished differently (in the virtual lab, black in matt and in shiny paint, matt white, and polished silver)
- kettle and heatproof mat
- infrared detector with a meter, or an infrared thermometer
- ruler, a thermometer for the water and a stopwatch
- for the absorbers: a radiant heater, two identical metal plates (one matt black, one shiny silver) on stands, two drawing pins and some wax
Variables
| Type | Emitters (Leslie cube) | Absorbers (two plates) |
|---|---|---|
| Independent | The type of surface | The type of surface |
| Dependent | The detector reading from each face | The time taken for the pin to fall |
| Control | The same water behind every face, an equal gap between the detector and each face, the detector aimed at the middle of the face, the same detector, faces of equal size | The same heater, equal distances from it, plates of the same metal and size, equal blobs of wax, plates starting at room temperature |
Because all four faces of the cube share the same hot water, they are all at the same temperature. That is what makes the Leslie cube a fair test: only the surface differs.
Method
Emitters
- Put the Leslie cube on the heatproof mat, then pour in hot water from the kettle without moving the cube. Put the lid on, with the thermometer through the hole.
- Set the detector 10 cm from the first face, measured with the ruler from the face itself, and point it straight at the middle of the face.
- Wait until the reading is steady. Write it down with the water temperature.
- Turn the cube a quarter turn to bring the next face round. Check the distance again and take the next reading. Carry on until you have read all four faces.
- Do two more rounds. In the second round go the other way round the cube, so that no face is always the last one read, when the water is coolest.
- Work out the mean reading for each face.
Absorbers
- Fix a drawing pin to the back of each plate with an equal blob of wax.
- Stand the plates facing the heater, the same distance from it on either side and level with it.
- Switch the heater on and start the stopwatch. Note the time at which each pin falls. Stop after 10 minutes if a pin is still on.
- Let the plates cool to room temperature, replace the wax, and repeat twice more.
Without a detector, a different version uses identical cans with different finishes, each holding the same volume of hot water and a thermometer. The can whose temperature falls fastest has the best emitter on its outside. Every can also loses energy to the air by convection, so the differences between them are smaller than a detector shows.
In the virtual lab above, Turn the cube and take the next reading moves the clock on 30 seconds, the time it takes to turn the cube, reset the detector and let the reading settle. Switch on the heater and time the pins runs one absorber test.
Risk assessment
| Hazard | Risk | Control |
|---|---|---|
| Hot water | Scalds | Pour the water in with the cube already on its mat and do not move it while full; mop up spills straight away; cool any scald under cold running water |
| Hot metal cube and radiant heater | Burns | Turn the cube by its base or with a heat-resistant glove; the heater stays hot after it is switched off, so leave it to cool |
| Water near mains equipment | Electric shock | Keep the kettle, the heater and their leads well away from the water |
Analysing the results
Put the readings in a table with one row for each face, one column for each round and a column for the mean, with the detector's unit in every heading. Compare the three readings for each face before averaging: if one is far from the other two, treat it as an anomaly, leave it out of the mean and look for the cause. A detector that has been nudged further from the face is a common one, because the reading falls quickly with distance.
Draw a bar chart of the means, not a line graph. What you changed was the kind of surface, which comes in named categories, not numbers: there is nothing between "matt white" and "shiny black" for a line to pass through. A line on each bar from the lowest to the highest repeat shows how far the readings spread.
The face that gives the largest mean reading emits infrared best. If the ranges of two faces overlap, your results cannot separate them.
Expect the readings to drift down during the experiment. In the model, water at 80 °C cools by about 0.5 °C a minute, and that lowers the reading from any face by roughly 1% a minute. Reversing the order in alternate rounds shares this out, so it does not always count against the same face.
Typical results
| Face | Round 1 / W/m² | Round 2 / W/m² | Round 3 / W/m² | Mean / W/m² |
|---|---|---|---|---|
| A matt black | 103.3 | 99.8 | 101.4 | 101.5 |
| B matt white | 62.2 (anomaly) | 95.0 | 94.9 | 95.0 |
| C shiny black | 93.4 | 92.5 | 93.4 | 93.1 |
| D shiny silver | 5.1 | 5.4 | 5.2 | 5.2 |
These come from the virtual lab, with water that starts at 80 °C and the detector set 10 cm from each face. The first reading from face B is far below the other two, because the detector had been knocked about 3 cm further back, so it is left out. Matt black gives the most infrared and shiny silver by far the least, about one-twentieth as much. Matt white is only about 6% behind matt black.
That last result surprises many students. White paint reflects most visible light, but the infrared from warm water has much longer wavelengths, and at those wavelengths white paint gives out nearly as much as black paint. Polished metal is what really stands apart: it reflects infrared well, so it absorbs and emits very little. Gloss black paint looks shiny, yet it still emits only a little less than matt black. In exam answers, rank matt (dull) surfaces above shiny ones and black above white, with matt black best and shiny silver worst.
In the absorber test, the black plate’s pin drops off after about a minute and a half, while the pin on the shiny silver plate is still in place after 10 minutes: in the model that plate warms only to about 24 °C. The surface that emits best also absorbs best: surfaces that take in infrared well also give it out well.
Evaluation
Detector position and distance. In the model, moving the detector from 10 cm to 11 cm away cuts the reading by about 14%. Measure the distance from the face before every reading, and always aim at the middle of the face, square on.
The water cools between readings. Each reading is taken with slightly cooler water than the one before. Work quickly, record the water temperature with every reading, and reverse the order of the faces in alternate rounds.
Background infrared. The room, the bench and your own body all give out infrared. Point the detector at something at room temperature first to check it reads close to zero, and keep your hands out of the space in front of the detector.
Repeats. Three rounds and a mean reduce random errors, such as small differences in where the detector is placed or a flickering meter. They cannot remove an error built into the method, such as reading the same face last in every round.
An infrared thermometer instead. It works out a temperature from the infrared it receives, and most are set up for surfaces that emit well, such as matt paint. Pointed at the shiny silver face, it shows a much lower "temperature", although every face is at the temperature of the water.
Absorbers. Warm air rising from the heater heats both plates a little, so stand them level with the heater, not above it. Equal blobs of wax matter, because a bigger blob takes longer to melt.
How the infrared practical is examined
Exam-style questions
1. Explain why every face of a Leslie cube filled with hot water is at the same temperature, and why this matters in the investigation. (2 marks)
2. A student plots the detector readings for the four faces. Explain why a bar chart is better than a line graph. (1 mark)
3. In every round, the student reads the faces in the same order, and each round's readings are lower than the round before. Explain why, and suggest how to reduce the effect on the comparison. (3 marks)
4. A student points an infrared thermometer at each face of a Leslie cube full of water at 80 °C. It shows 80 °C for the matt black face but only about 25 °C for the shiny silver face. Explain why the readings differ, even though both faces are at the same temperature. (2 marks)