Two quantities, one unit
Electromotive force (e.m.f.) and potential difference (p.d.) are both measured in volts (V), and both are about energy and charge. They describe opposite ends of the same energy story. The definitions and the use of voltmeters are Core. The two equations are Supplement.
Electromotive force (Core)
A cell, battery, generator or power supply is a source. It does work on charge, pushing it all the way round a complete circuit. The e.m.f. of the source is the electrical work it does in moving one unit of charge (one coulomb) right round that circuit.
So a 1.5 V cell does 1.5 J of work on every coulomb it sends round the loop. A 12 V car battery does 12 J on each coulomb. Despite its name, e.m.f. is not a force. It is measured in volts, just like p.d.
Potential difference (Core)
As charge passes through a component, such as a lamp, a heater or a motor, it does work and energy is transferred to the component and then to the surroundings. The p.d. across the component is the work done by one unit of charge as it passes through that component.
One volt means one joule of work for each coulomb: 1 V = 1 J/C. A lamp with a p.d. of 3 V across it receives 3 J from every coulomb that flows through it.
The difference is the direction of the energy transfer:
- e.m.f.: energy is given to the charge by the source
- p.d.: energy is given by the charge to a component
In a simple loop with one cell and one lamp, the energy the cell gives each coulomb is the energy that coulomb hands over in the lamp, so the two values match (ignoring tiny losses in the wires and inside the cell).
Measuring p.d. with a voltmeter (Core)
A voltmeter is always connected in parallel, across the component, with one lead on each side. In effect, it compares the energy per coulomb on the two sides of the component. A good voltmeter has a very large resistance, so almost no current flows through it.
Cambridge expects you to know about analogue and digital voltmeters and their ranges:
- With an analogue voltmeter, check the zero first and look straight at the needle to avoid parallax error.
- A digital voltmeter gives a number; its last digit sets the resolution.
- On a meter with ranges such as 0–3 V and 0–15 V, a p.d. of about 2 V is best measured on 0–3 V. The reading then fills more of the scale and is more precise. If the p.d. might exceed 3 V, start on 0–15 V.
Placing a voltmeter directly across the terminals of a source gives a reading for its e.m.f. when little or no current is being drawn.
Worked example (Supplement)
A 12 V car battery sends 50 C of charge round a circuit. Calculate the work done by the battery.
Given: V, C.
Equation: rearrange to .
Substitution:
Answer: 600 J.
A second case uses the p.d. equation. A lamp transfers 36 J of energy when 15 C passes through it. Then V.
Measure both in the simulation
In the simulation above, connect a cell to a resistor in a single loop. Add one voltmeter across the cell and a second across the resistor. Select the cell and change its e.m.f.: both readings change together and stay equal. With only one component in the loop, every joule the cell gives a coulomb is handed over in the resistor. Now add a second resistor to the loop and measure across each one. The two p.d.s split the energy from the cell between them.