What AQA expects (WS 2.7 and WS 3.7)
These skills are examined on both tiers, in Physics and Combined Science, usually within a required practical. No equation is involved. Be ready to:
- judge data as accurate, precise, repeatable or reproducible
- name sources of random and systematic error, and reduce them
- find a mean, range and uncertainty (WS 3.3 and WS 3.4)
- deal with anomalies (WS 3.7) and improve a method (WS 2.7)
The words to use
| Word | What it means |
|---|---|
| True value | What an error-free measurement would give; a data-book value usually stands in for it. |
| Accurate | Near the true value. |
| Precise | Repeats bunch tightly, wherever the true value is. |
| Repeatable | The same investigator, method and equipment give similar results again. |
| Reproducible | Results still agree when another investigator repeats the work with different equipment, or when a different method is used. |
| Anomaly | A result that breaks the pattern set by the rest. |
Resolution and zero error are general terms, not defined in the specification, but questions use them. Resolution is the smallest step by which a reading can change: 0.01 s on a stopwatch showing 12.47 s. A zero error is a reading that is not zero when nothing is being measured. Fine resolution is no guarantee of accuracy: a thermometer showing tenths of a degree can still read 2 °C high.
Random and systematic errors
Random errors scatter repeats unpredictably, some high and some low: reaction time on a stopwatch, a flickering display, a draught over a balance. They spoil precision. In a mean of more readings, the highs and lows partly cancel.
Systematic errors shift every reading away from the true value by the same amount: a zero error, a thermometer that reads high, always viewing a scale from above. Data can then be precise yet inaccurate, and repeating cannot help: find the cause and correct for it.
Worked example 1: two zero errors
(a) An empty digital balance shows 0.06 g. A brass mass then reads 50.36 g.
(b) Before switch-on, an ammeter needle rests at −0.04 A. With current flowing it shows 0.48 A.
Subtracting a negative zero error adds it on. Better still, zero the instrument first.
Mean, range and uncertainty
WS 3.4 treats every measurement as uncertain, judging how much from the spread of the repeats about their mean. Write the result as mean ± half the range.
Worked example 2: a falling paper cone
A paper cone dropped from 1.50 m is timed five times: 1.26 s, 1.18 s, 1.21 s, 1.63 s and 1.23 s.
Anomaly: 1.63 s. The notes say the cone clipped a stool, a poor measurement, so it is ignored.
Range: s. Uncertainty: s. Result: s.
Keeping 1.63 s would give a mean of 1.30 s and a range of 0.45 s. With no known cause, repeat the drop rather than delete the value.
Evaluating a method (WS 2.7)
- Enough readings? Repeats at each value, over a wide range.
- Precise enough? A wide spread means random error; light gates or a data logger remove reaction time.
- Systematic error? Look for results all high or all low against an accepted value, or a line missing the origin when it should pass through it.
- Valid? The method answers the question, with control variables fixed.
Using the simulation
In the simulation above, five shots from a steady shooter open the Target view, labelled Accurate and precise.
- In the set-up menu beside Clear, swap Both for Precise only. The new group is tight but off-centre: Accuracy gets a cross, Precision a tick. Drag Sight offset to 0 and the group slides home unchanged.
- Choose Readings and press Read 5. The ruler's worn end adds 2 mm, so the 86.6 mm pencil reads 88 or 89 mm. Press Read 5 three more times: Mean − true value stays near +2 mm. Drag Zero error (worn end) to 0 and it drops to 0.0 mm.
- Switch on Include an odd reading (number 4). Keep it is chosen first; try Leave out and Repeat it, watching Range and Uncertainty (½ range).
- Choose Resolution and press Measure. A ball 12.374 mm across reads 13 mm (ruler), 12.6 mm (Vernier callipers) and 12.57 mm (micrometer): all too big, because of a shared +0.20 mm zero error. Drag the zero error slider to 0 to see 12 mm, 12.4 mm and 12.37 mm.
On a phone, sliders are in the Controls tab below the stage, cards in the Readings tab.