What this topic covers
Radiotherapy staff in Lahore, engineers checking pipeline welds in Alberta and school technicians all work close to radioactive sources. This page (syllabus 5.2.5) explains why ionising radiation is harmful and how sources are kept under control.
Harm to living things (Core)
As ionising radiation passes through a cell, it knocks electrons out of atoms and molecules. The ions it leaves behind can break or alter the molecules the cell depends on, including its DNA.
- Cell death. A large dose kills cells outright. Very large doses kill so many that they cause burns and radiation sickness.
- Mutations. Damaged DNA may be copied with errors in it. A mutation in a sperm or egg cell can be passed on to a child.
- Cancer. A cell with damaged DNA may begin dividing out of control and form a tumour.
The bigger the dose, the greater the risk. Radiotherapy uses the cell-killing effect on purpose to destroy tumours.
Outside the body, alpha is stopped by clothing or dead skin, but beta and gamma reach living cells. Inside the body, an alpha source does the most harm, as all its intense ionisation happens in neighbouring cells.
Handling sources safely (Core)
| Stage | Typical precautions |
|---|---|
| Storing | Each sealed source sits in a lead-lined box, inside a locked cupboard marked with the radiation warning sign. A log records where every source is. |
| Using | Trained staff lift sources with long tongs, never fingers, hold them at arm's length, point them away from everyone and return them as soon as the experiment ends. |
| Moving | Sources travel inside shielded, labelled containers. Very strong ones are handled by remote-controlled arms behind thick walls with lead-glass windows. |
Time, distance and shielding (Supplement)
Every precaution in the table works in at least one of three ways.
- Shorter exposure. At a steady rate, the radiation absorbed is proportional to the time exposed: halve the time and you halve the dose.
- Greater distance. Radiation spreads out, so less reaches each square centimetre of skin further away; air also absorbs alpha within a few centimetres. Tongs and arm's length rely on this.
- Shielding. Material between the source and the body absorbs radiation. Paper is enough for alpha and a few millimetres of aluminium for beta, but gamma needs thick lead or concrete and is never stopped completely.
Worked example: testing a shield (Supplement)
A technician tests a lead screen for a gamma source. With the source locked away, the counter reads 24 counts/min. With the source in place it reads 984 counts/min, and 144 counts/min once the screen is put in between.
(a) Corrected count rates. Without the screen: 984 − 24 = 960 counts/min. With it: 144 − 24 = 120 counts/min.
(b) Fraction getting through. 120 ÷ 960 = 0.125, one eighth. The screen absorbs the other seven eighths.
(c) Why not divide 144 by 984? The background is there with or without the screen, so it must be taken away first. The uncorrected ratio, about 0.15, makes the screen seem less effective than it really is.
Seeing the three rules at work
In the simulation above, the Safety in a real lab box under the stage sums up how school sources are treated. The experiments show why each rule works (Supplement). Wherever a step below says Skip, press it to finish that count at once. Counts are random, so yours will differ a little from the values given.
- Time. Choose Gamma under Source and press Skip: a 1-minute count gives about 1200 counts. Set Count for to 10 s and press Skip: only about 200. The rate is unchanged, so six times as long means six times the radiation. Then return Count for to 1 min.
- Shielding. Move Source to tube to 6 cm and press Skip: the corrected count rate is about 320 counts/min. Choose Lead, set Lead thickness to 1.2 cm and press Skip, then set 2.4 cm and press Skip again. The corrected rate drops to about 160, then about 80, never to zero.
- Distance. Press Range under the stage and set Tube distance from the source to 3, 6 and 12 cm in turn, pressing Skip at each. The corrected count rate falls from about 1200 to about 320, then about 80. Choose Alpha, set the tube to 5 cm and press Skip: only background is left (exact ranges in air are beyond the syllabus).