Skip to content

Atomic and nuclear physics simulation

Alpha, Beta and Gamma Radiation Simulation

A virtual radiation bench: a lead-lined source holder, absorber sheets and a Geiger–Müller tube with a clicking counter. Identify mystery sources from corrected count rates, measure ranges in air, bend beams in electric and magnetic fields and compare ionising power.

Loading simulation…
Show symbols for

Predict first

Question 1 of 4

A beta source sits 3 cm from a GM tube. A sheet of paper is slipped in between them. What happens to the corrected count rate?

Try this

  1. 1In Penetration, keep the Alpha source with no absorber and press Play for a 1 min count. Then choose Paper as the absorber and count again. How does the new count rate compare with the background?
  2. 2Choose None under Source and count for 1 min to measure the background. Then choose Beta and count with None, Paper and Aluminium (3 mm). Take the background away from each count rate in the Results table. Which absorber makes the difference?
  3. 3Choose Gamma and Lead, and set Source to tube to 6 cm. Try a lead thickness of 1.2 cm, then 2.4 cm, then 3.6 cm, pressing Skip for a quick count each time. What happens to the corrected count rate every time you add another 1.2 cm?
  4. 4Choose Unknown as the source. Use Skip to make quick counts with no absorber, paper and aluminium, and with no source for the background. Switch on the radiation you think it gives out and press Check, then press New unknown for another.
  5. 5Open Fields, choose Magnetic and press Play. Which way does each beam bend? Press Flip, then switch to Electric and note which plate each beam moves towards.

What is on the bench

The simulation puts a sealed radioactive source in a lead-lined holder and aims it at the end window of a Geiger–Müller tube. The tube is wired to a counter whose lamp flashes, and whose display ticks up, every time radiation sets off a pulse in the gas. Four buttons under the stage switch between the experiments: Penetration, Range, Fields and Ionising. Radiation itself is invisible, so the glowing tracks are only a drawing. Alpha shows as short thick streaks, beta as thin jittery lines and gamma as faint ripples.

Counts that never repeat exactly

Radioactive decay is random, so two one-minute counts of the same set-up almost never agree. The counter is built the same way. Each tiny slice of time receives a whole number of counts drawn from a Poisson distribution, so a count near 400 usually lands within about 20 of it, roughly its square root. Longer counts give steadier rates. Even with the holder empty the tube still clicks now and then, because radon gas, rocks, building materials and cosmic rays supply a background. Its value here is adjustable and approximate. Subtract it from every reading before you compare anything.

What stops each kind

Slide absorbers in between and watch the corrected count rate. One sheet of paper removes every alpha particle. Beta particles slip through paper, losing only a few per cent, yet a couple of millimetres of aluminium takes them all. Gamma rays barely notice paper or aluminium. Lead cuts them down: in this model each 1.2 cm of lead halves what arrives, a figure typical of gamma rays from cobalt-60. Halving again and again never quite reaches zero, so some gamma always gets through. Thick lead needs a wider gap, and moving the tube back lowers the count by itself, so keep the distance fixed while you compare thicknesses.

Choosing Unknown turns all this into a puzzle. Several of the seven mystery sources emit two or three kinds at once.

Range in air

The Range experiment leaves only air between source and tube. Alpha readings collapse to background somewhere between 4 and 5 cm, where the particles run out of energy. Beta readings sink faster than spreading out would explain, because the air gradually absorbs them. Gamma readings drop too, almost entirely because the rays spread over a larger area, and the dashed curve on the graph traces that inverse-square trend.

Beams in fields

Fields sends all three beams through a vacuum chamber. Between charged plates the positive alpha particles curve towards the negative plate, while the much lighter beta particles swing further towards the positive one. In a magnetic field the push on a moving charge is at right angles to both its motion and the field. Alpha and beta carry opposite charges, so they bend opposite ways, and gamma carries straight on. The true magnetic bend of alpha is around 70 times gentler than that of a typical beta particle, too small to see clearly, so by default it is drawn 20 times larger. Turn that off to see the real proportions. Deflection is in the Cambridge IGCSE Supplement and the Punjab Class 10 book, but not in AQA GCSE.

Ionising power

The Ionising view magnifies one centimetre of air. A typical alpha particle leaves around 40 000 ion pairs in it, a beta particle about 100 and a gamma ray about one on average. A big charge, a modest speed and plenty of kinetic energy make alpha the strongest ioniser, which is exactly why it is stopped so soon.

In a real lab

School sources are sealed, stored in lead-lined boxes and moved with tongs at arm's length, never pointed at anyone and used only briefly. Less time, more distance and good shielding all reduce the dose.

Check your understanding

8 questions

  1. 1.A source sits close to a GM tube. Putting one sheet of paper in between makes the corrected count rate fall to zero. What does the source give out?
  2. 2.Why is the background count rate taken away from every reading?
  3. 3.Which absorber is enough to stop the beta particles from a school source?
  4. 4.Every 1.2 cm of lead halves the number of gamma rays from a source that get through. What fraction of them gets through 2.4 cm of lead?
  5. 5.Why do alpha particles travel only a few centimetres through air?
  6. 6.Alpha particles moving to the right through a magnetic field bend up the screen. Which way do beta particles, also moving to the right, bend in the same field?
  7. 7.Alpha, beta and gamma pass between two charged plates. Which of them goes straight on?
  8. 8.A tube reads 25 counts/min with no source and 85 counts/min with the source in place. What is the corrected count rate?

For teachers

Embed it in your site or open it full-screen for the projector.

Read more