Skip to content

GCSE Physics — AQA · Atomic structure

Uses and hazards of radiation

4.4.3.14.4.3.24.4.3.3Physics only

GCSE Physics only. Background radiation comes from natural sources such as rocks and cosmic rays and from human activity; dose, in sieverts, depends on job and location. A short half-life means an intense but brief hazard. Hospitals use gamma tracers to see organs and radiation to destroy tumours.

Loading simulation…

Symbols match your course. Open the full alpha, beta and gamma radiation simulation for more presets and teacher tools.

Physics only: spec points 4.4.3.1 to 4.4.3.3

This page is GCSE Physics only, on both tiers; Combined Science papers leave it out. There is no equation. Aim to be able to:

  • list where background radiation comes from, and say why a job or a home town can raise a person's dose
  • handle doses in sieverts (questions give the unit), with 1 Sv = 1000 mSv
  • explain how half-life affects the hazard from a radioactive material
  • describe how hospitals use radiation to see inside the body and to kill or shrink unwanted tissue, and weigh each use against its risks using data

Contamination and irradiation (4.4.2.4), summarised below, are for all students.

Background radiation

Low levels of radiation reach us constantly, wherever we are: this is background radiation.

  • Natural: rocks and soil, including radon gas seeping from the ground; cosmic rays from space; traces of radioactive isotopes in food and in our bodies.
  • Man-made: dust from nuclear bomb tests and material released by accidents such as Chernobyl in 1986. (Medical X-rays also add to a person's yearly dose, but AQA's examples of man-made background are fallout and accidents.)

Location and occupation both matter. Homes on granite, as in parts of Cornwall, collect more radon. Airline crews spend long hours high up, where cosmic rays are stronger. Hospital and nuclear workers wear badges that record their dose.

Radiation dose describes the risk of harm from the radiation a body absorbs. Its unit is the sievert (Sv), and everyday doses are quoted in millisieverts: 1 mSv = 0.001 Sv.

Worked example: correcting for background

With no source nearby, a GM tube records 63 counts in 3 minutes. With a source in place, it records 1530 counts in 5 minutes.

  1. Background count rate: 63÷3=2163 \div 3 = 21 counts per minute.
  2. Count rate with the source: 1530÷5=3061530 \div 5 = 306 counts per minute.
  3. Corrected count rate: 306−21=285306 - 21 = 285 counts per minute, or 285÷60≈4.8285 \div 60 \approx 4.8 counts per second.

Half-life and hazard

Half-lives vary enormously: about 6 hours for technetium-99m, 8 days for iodine-131, 5.3 years for cobalt-60 and 4.5 billion years for uranium-238.

  • Short half-life: for the same number of unstable nuclei, activity is higher and the danger intense, but brief: two days after a technetium-99m scan, under 1% of the activity remains.
  • Long half-life: activity is lower but can last for thousands of years or more, so nuclear waste stays hazardous for generations.

Radiation in medicine

UseHow it worksWhy this choice
Looking inside the bodyA tracer such as technetium-99m is injected; a gamma camera outside the body maps where it collects.Gamma escapes the body and ionises weakly. A half-life of hours covers the scan, then fades.
Destroying a tumour from outsideNarrow gamma beams aimed from several directions cross at the tumour.The tumour gets a large dose; healthy tissue on each path gets much less.
Treating tissue from insideSwallowed iodine-131 gathers in the thyroid gland.Its beta particles travel only a short way through tissue, so the damage stays local.

Ionising radiation can damage cells and cause cancer, so each use is a balance: a scan adds a small dose, but early diagnosis saves lives. Judge risk from data, not fear.

Contamination or irradiation?

Irradiation: an object sits in the path of radiation from a source outside it. It stops when the source is removed or blocked, and the object does not become radioactive: gamma-sterilised syringes are safe. Contamination: radioactive atoms have ended up on or inside something where they are not wanted, and they keep decaying until removed. Swallowed or breathed in, an alpha emitter is the most dangerous; outside the body, skin absorbs alpha.

In the simulation above

  1. Choose None under Source and press Play. With the holder empty, the rate settles near 20 counts/min: the Background count rate setting.
  2. Choose Gamma and press Skip: about 1220 counts/min. Subtract the background, then compare with the Corrected count rate card, about 1200.
  3. Choose Lead under Absorber and count again. Its starting 2 cm cuts the rate to about 400 counts/min: shielding at work.
  4. Open Range, keep Gamma, set Tube distance from the source to 6 cm and count. The corrected rate falls to about 320 counts/min: distance protects too.

Common mistakes

  • Forgetting to subtract the background count rate, or taking a per-minute background away from a per-second reading. Put both rates in the same unit, then subtract.
  • Saying an irradiated object becomes radioactive. Irradiation exposes it to radiation from a source outside it; once the source is gone, nothing radioactive remains. Only contamination leaves radioactive atoms behind.
  • Claiming a long half-life always means more danger. For the same number of nuclei, a short half-life gives a higher activity that soon dies away; a long half-life gives a lower activity that lasts far longer.
  • Choosing an alpha or beta emitter as a medical tracer. A tracer must emit gamma, which passes out of the body to reach the detector and ionises only weakly. Alpha would be stopped inside the body and damage nearby cells; beta would also be partly absorbed, giving a weaker signal and a larger dose.
  • Thinking background radiation is mostly man-made. Most of it is natural: radon gas from the ground, rocks, cosmic rays and the isotopes in food and our bodies.
  • Calling alpha harmless because paper stops it. Outside the body it is the least hazardous, but an alpha emitter that is swallowed or breathed in is the most dangerous, because it ionises cells so strongly at close range.

Exam-style questions

Original questions written in the style of GCSE AQA. Try each one before you reveal the answer.

  1. 1.A student uses a Geiger–Müller tube and counter in a school laboratory. With no source nearby, the counter records 54 counts in 3 minutes. A radioactive source is then placed in front of the tube, and the counter records 2316 counts in 4 minutes.

    1. (a)Give two natural sources of background radiation.

      2 marks
      Show the answer

      Answer: Any two from: rocks or soil (including radon gas from the ground), cosmic rays from space, radioactive isotopes in food, drink or the body.

      Marking points

      • First natural source, e.g. rocks / radon gas
      • Second natural source, e.g. cosmic rays / food and drink
    2. (b)Calculate the corrected count rate due to the source alone, in counts per minute.

      3 marks
      Show the answer

      Answer: Background = 54 ÷ 3 = 18 counts per minute. With the source = 2316 ÷ 4 = 579 counts per minute. Corrected count rate = 579 − 18 = 561 counts per minute.

      Marking points

      • Background count rate = 18 counts per minute
      • Count rate with the source = 579 counts per minute
      • Corrected count rate = 561 counts per minute
    3. (c)A school in another town measures a higher background count rate. Suggest a reason for this.

      2 marks
      Show the answer

      Answer: The ground under that town may contain rocks such as granite, which give off more radon gas, so more radiation reaches the detector.

      Marking points

      • Different rocks under the town (e.g. granite) (allow: the town is at a higher altitude)
      • Which release more radon gas / give off more radiation (allow: where cosmic rays are more intense)
  2. 2.At high altitude, an airline pilot receives an extra radiation dose of 0.004 mSv for every hour of flying. In one year the pilot flies for 650 hours. The background dose where the pilot lives is 2.3 mSv per year. (1000 mSv = 1 Sv)

    1. (a)Calculate the extra dose the pilot receives from flying in that year, in mSv.

      2 marks
      Show the answer

      Answer: 0.004 × 650 = 2.6 mSv

      Marking points

      • 0.004 × 650
      • 2.6 mSv
    2. (b)Write your answer to the previous part in sieverts.

      1 mark
      Show the answer

      Answer: 2.6 ÷ 1000 = 0.0026 Sv

      Marking points

      • 0.0026 Sv (allow their previous answer ÷ 1000)
    3. (c)Explain why airline crews receive a higher radiation dose than people who work in offices.

      2 marks
      Show the answer

      Answer: They spend many hours at high altitude, where there is less atmosphere above them to absorb cosmic rays from space, so the cosmic radiation is more intense.

      Marking points

      • They spend long periods at high altitude
      • Where cosmic rays (from space) are more intense / less atmosphere absorbs them
    4. (d)The pilot says the extra dose from flying is too small to matter. Use the data to evaluate this claim.

      2 marks
      Show the answer

      Answer: The extra 2.6 mSv is slightly more than the 2.3 mSv background dose, so flying more than doubles the pilot's yearly dose. The dose is still small, but it does add to the risk, so it is sensible to monitor the hours flown.

      Marking points

      • Comparison: the extra dose (2.6 mSv) is about the same as, or a little more than, the background dose (2.3 mSv), so the total is roughly doubled
      • Conclusion: still a small dose, but not negligible, as risk increases with dose (allow any reasoned conclusion that uses the numbers)
  3. 3.A doctor wants to check how well a patient's kidneys are working. A radioactive tracer will be injected into the patient's blood, and a detector outside the body will show where it goes. The doctor can choose from four isotopes: P emits alpha, half-life 6 hours; Q emits gamma, half-life 6 hours; R emits gamma, half-life 30 years; S emits beta, half-life 2 days.

    1. (a)Which isotope should the doctor use? Explain your choice.

      4 marks
      Show the answer

      Answer: Q. It emits gamma, which passes out of the body and can be detected outside. Gamma is only weakly ionising, so it does less damage to the patient's cells than alpha or beta. A half-life of 6 hours is long enough for the test but short enough for the activity to fall quickly afterwards, so the patient's total dose is small.

      Marking points

      • Q
      • Gamma passes out of the body to reach the detector
      • Gamma is weakly ionising, so it causes less damage to cells
      • 6 hours is long enough for the test, but the activity falls quickly afterwards, keeping the dose small
    2. (b)Explain why isotope R is not suitable, even though it emits gamma rays.

      2 marks
      Show the answer

      Answer: Its half-life of 30 years is very long, so its activity would stay almost the same for years. The patient would keep receiving a dose long after the test was over.

      Marking points

      • Half-life is very long, so it stays radioactive (its activity stays high) for many years
      • So the patient goes on receiving a dose long after the test
    3. (c)After the injection the patient is contaminated, not just irradiated. Explain the difference between contamination and irradiation.

      2 marks
      Show the answer

      Answer: Contamination means radioactive material is on or inside the patient, so it keeps emitting radiation until it decays or is removed. With irradiation, the radiation comes from a source outside the body; it stops when the source is removed and leaves nothing radioactive behind.

      Marking points

      • Contamination: radioactive atoms / material on or inside the person, which go on emitting radiation
      • Irradiation: the radiation comes from a source outside the person, who does not become radioactive
  4. 4.Gamma rays can be used to destroy a tumour deep inside a patient's body. Several narrow beams are aimed at the tumour from different directions.

    1. (a)Explain why several beams from different directions are used, rather than a single beam.

      2 marks
      Show the answer

      Answer: All the beams pass through the tumour, so it receives a large total dose. Each beam passes through a different part of the healthy tissue, so the healthy tissue receives a much smaller dose.

      Marking points

      • The beams all meet / overlap at the tumour, so it receives a large dose
      • Healthy tissue along each path receives only a small dose
    2. (b)Explain why gamma rays are used from outside the body rather than alpha particles.

      2 marks
      Show the answer

      Answer: Alpha particles would be absorbed by the skin and could not reach the tumour. Gamma rays penetrate deep into the body.

      Marking points

      • Alpha would be absorbed by the skin / has a very short range
      • Gamma is very penetrating, so it can reach a tumour deep inside the body
    3. (c)Give two ways that hospital staff reduce their own radiation dose during these treatments.

      2 marks
      Show the answer

      Answer: Any two from: operate the machine from outside the room, behind lead or concrete shielding; keep as far from the source as possible; keep the time spent near the source short.

      Marking points

      • First method, e.g. shielding (lead or thick concrete walls)
      • Second method, e.g. distance (controls outside the room) or limiting time near the source

Quick check

6 questions

  1. 1.Which of these is a natural source of background radiation?
  2. 2.A worker receives a radiation dose of 0.0035 Sv in one year. What is this dose in millisieverts? (1000 mSv = 1 Sv)
  3. 3.Why is a gamma emitter chosen as a medical tracer?
  4. 4.Surgical tools sealed in plastic are sterilised with gamma rays. What happens to the tools?
  5. 5.Samples X and Y contain the same number of unstable nuclei. X has a half-life of 2 hours; Y has a half-life of 2 years. Which statement is correct?
  6. 6.A tube reads a background of 24 counts per minute. With a source in place it reads 150 counts per minute. What is the corrected count rate?