What this topic covers
Half the technetium-99m in a Santiago hospital bone scan decays in about 6 hours; half the americium-241 in a smoke alarm takes about 430 years. This page (syllabus 5.2.4) explains half-life, its calculations and how it helps decide which isotope to use. Decay itself is covered in 5.2.3.
Count rates are in counts/s or counts/minute (5.2.1); activity and becquerels are beyond this syllabus.
What half-life means (Core)
Start a clock with any sample of one isotope. The half-life is the time on the clock when half of those nuclei have decayed. Each later half-life halves what is left: 6400, 3200, 1600, 800 undecayed nuclei. A full definition carries five ideas: a time, half, the nuclei of that isotope, any sample, and decay.
Amount, temperature and chemical form make no difference to it. The count rate halves in the same time, which is how half-lives are measured.
Worked example: a Core calculation
Given: a sample holds undecayed nuclei of an isotope whose half-life is 2.5 days. Find how many are left after 10 days.
- Number of half-lives: .
- Four halvings divide by : .
- Fraction left: 1/16 = 0.0625.
Answer: undecayed nuclei.
On a decay curve, read across from half the starting count rate, then down.
When background is included (Supplement)
Background adds the same amount to every reading and never decays, so a measured curve levels off at the background count rate. Subtract it from every value before halving.
Given: a measured decay curve flattens out at 0.5 counts/s. It reads 6.5 counts/s at the start, 3.5 counts/s at 40 s and 2.0 counts/s at 80 s.
- Background: 0.5 counts/s, where the curve flattens.
- Corrected count rates: 6.0, 3.0 and 1.5 counts/s, halving every 40 s.
Answer: half-life = 40 s. Halving the measured 6.5 counts/s instead gives 3.25 counts/s, not reached until about 45 s: too long.
Choosing an isotope (Supplement)
The radiation must reach its target; the half-life must suit the job's length.
| Job | Radiation | Half-life |
|---|---|---|
| Smoke alarm (americium-241) | Alpha: strongly ionising, yet too short-ranged to escape the case | About 430 years: steady for the alarm's life |
| Irradiating food, sterilising equipment (cobalt-60) | Gamma: passes through packaging to kill bacteria, leaving nothing radioactive | About 5.3 years: years of use between replacements |
| Gauging paper or thin sheets (strontium-90) | Beta: partly absorbed, so the count rate tracks the thickness (alpha would all be stopped; gamma suits thick steel) | About 29 years: count changes come from the sheet, not the source |
| Diagnosing cancer as a tracer (technetium-99m) | Gamma: leaves the body to reach a camera, ionising little | About 6 hours: lasts the scan, then soon dies away |
| Treating cancer with beams (cobalt-60) | Gamma: penetrating beams from several directions meet at the tumour | About 5.3 years: one source lasts for years |
These are the usual textbook choices, and real practice varies. Many hospitals now aim X-ray beams from machines at tumours instead of cobalt-60, and some food and equipment is sterilised with electron beams. In an exam, justify each choice from its radiation and its half-life, as the table does.
Trying it yourself
In the simulation above, choose Radon-220 under Isotope; the run restarts, paused.
- (Core) Press Play. Text under the graph gives the time when half of the 400 nuclei had decayed: about 56 s, against the Half-life T½ card's 55.6 s.
- (Core) After the run, press ⅛ under Half-life line at: about 157 s, three halvings of about 52 s. Press Reset, choose 3 under Pause after, then Play. When it stops, compare This sample with Expected N (50).
- (Supplement) Set Pause after to Off. Then choose 1600 under Nuclei at the start and set Background count rate to 1.0 counts/s; each of these two changes restarts the run, paused. (400 nuclei give only about 1 count/s from the source.) Switch the graph to Count rate and press Play. When the run is over, the corrected count rate takes about 57 s to halve; switch off Subtract the background and the recorded readings take about 76 s.
- (Supplement) Under Choose an isotope for the job, select Paper gauge, try each isotope, then press Show the usual choice.