Cambridge IGCSE Physics (0625) · Electric circuits and electrical safety

Electrical safety

4.4

A mains circuit has live (line), neutral and earth wires, with the switch and fuse in the live one. Learn four hazards, how fuses and trip switches work, how to choose a fuse rating from P = IV, and why a casing is earthed or double-insulated. All of 4.4 is Core.

Loading simulation…

Symbols match your course. Open the full mains electricity and safety simulation for more presets and teacher tools.

What this topic covers

Live, neutral and earth (Core)

The live (or line) wire is at a high alternating p.d. The neutral wire is the return path, at about 0 V. The earth wire is joined to any metal casing and carries a current only in a fault. In the UK these are brown, blue, and green and yellow, and the mains is nominally 230 V at 50 Hz.

The switch goes in the live wire, so that opening it disconnects the appliance from the high p.d. A switch in the neutral would leave the parts inside live when off.

Four hazards (Core)

  • Damp. Impure water conducts, so wet skin or floors let current pass more easily through someone to earth.
  • Overloading. Appliances sharing one socket, adaptor or extension lead are in parallel, so their currents add. Too large a total overheats the plug, socket or lead.
  • Damaged insulation. A cracked cable can expose a live conductor (a shock risk) or let live touch neutral: a short circuit.
  • Overheating cables. Too much current for a cable, or a lead left coiled up, can make it hot enough to melt its insulation and start a fire.

Fuses and trip switches (Core)

A fuse is a thin wire in a holder, placed in the live wire. If the current rises above its rating, the wire melts and breaks the circuit; the fuse must then be replaced.

A trip switch (circuit breaker) is an automatic switch in the live wire. In a common design, too large a current makes an electromagnet strong enough to pull an iron catch, and spring-loaded contacts then snap open. It acts faster than a fuse, and after the fault is fixed it is reset, not replaced.

Find the normal current from P=IVP = IV and choose the smallest fuse rating above it. Too low, and the fuse melts in normal use. Too high, and a fault current that overheats the cable might not melt it. A trip switch is set the same way: above the largest normal current, but within what its cables can carry.

Worked example (Core): a fan heater

A 2.0 kW fan heater runs on a 230 V supply. Choose from fuses of 1 A, 3 A, 5 A, 10 A and 13 A.

Given: P=2.0P = 2.0 kW =2000= 2000 W, V=230V = 230 V

Equation: P=IVP = IV, so I=PVI = \dfrac{P}{V}

Substitution: I=2000230I = \dfrac{2000}{230}

Answer: I=8.7I = 8.7 A. A 5 A fuse is too small for everyday use. Choose 10 A, the smallest rating above 8.7 A. A 2.5 kW kettle takes 10.9 A, so it needs 13 A.

Earthed or double-insulated (Core)

A metal casing must be earthed. If a loose live wire touches it, a large current flows to earth along the low-resistance earth wire. This melts the fuse, or opens the trip switch, cutting the casing off from the live supply. Unearthed, it would stay at the mains p.d., a shock hazard.

A double-insulated appliance has an insulating outer casing, such as plastic, so it cannot become live and needs no earth wire. Its fuse still protects the circuit and the cable: if live touches neutral inside, the large current melts it.

In the simulation above

The Plug scene, shown first, goes beyond the syllabus.

  1. Press Faults under the stage. With Earthed metal case, press Fault: about 230 A flows in the earth wire until the kettle's 13 A fuse melts. Then pick No earth wire and press Fault again: the fuse survives, but the Case card shows 230 V.
  2. Choose Double insulated (a hairdryer with a 5 A fuse) and press Fault: no fault current flows. Under Fault, pick Short circuit and press the Fault button: the fuse melts, with no earth wire at all.
  3. Press Fuse and pick Fan heater (2 kW) under Appliance. Choose 5 A and press Switch on: it melts in normal use. Choose 10 A, press Switch on, then Fault: the overload melts it.
  4. Press Home and choose Kettle and heater on together from Examples: 19.6 A trips the sockets circuit's 16 A trip switch. Turn off Fan heater (2 kW), then press Reset.

Equations

  • Electrical power (P = IV)

    Learn this

    P=VI

    power = potential difference × current

    Open calculator →

Common mistakes

  • Picking a fuse rating that is not above the normal current. A kettle taking 10.9 A would melt a 10 A fuse, so it needs 13 A.
  • Fitting a much bigger fuse 'to be safe'. A rating far above the normal current may let a fault current overheat the cable without melting.
  • Saying a double-insulated appliance needs no fuse. It needs no earth wire, but its fuse still protects the circuit and the cable.
  • Putting the switch or the fuse in the neutral wire. The appliance stops working, but the parts inside stay at the live p.d.
  • Leaving the power in kilowatts when working out I = P ÷ V. Change 2.0 kW to 2000 W first.
  • Explaining earthing only as 'the current goes into the ground'. Go on to say that this big current blows the fuse, or opens the trip switch, so the live supply is cut off.

Exam-style questions

Original questions written in the style of Cambridge IGCSE. Try each one before you reveal the answer.

  1. 1.A metal kettle has a power of 2.4 kW. It is used on a 230 V supply.

    1. (a)Calculate the current in the kettle in normal use.

      2 marks
      Show the answer

      Answer: I = P ÷ V = 2400 ÷ 230 = 10.4 A

      Marking points

      • I = P ÷ V or 2400 ÷ 230
      • 10.4 A (accept 10.43 A)
    2. (b)Fuses rated 3 A, 5 A, 10 A and 13 A are available. State which fuse should be fitted and explain your choice.

      2 marks
      Show the answer

      Answer: 13 A. It is the smallest rating above the normal current of 10.4 A; a 10 A fuse would melt every time the kettle was used.

      Marking points

      • 13 A
      • smallest rating above 10.4 A / a 10 A fuse would melt in normal use
    3. (c)The live wire comes loose inside the kettle and touches the metal casing. Explain how the earth wire and the fuse together protect the user.

      3 marks
      Show the answer

      Answer: The fault joins live to earth through the casing and the low-resistance earth wire, so a very large current flows. This current is much larger than the fuse rating, so the fuse melts. The kettle is then cut off from the live supply, so the casing is not live and cannot give a shock.

      Marking points

      • large current flows through the casing and the (low-resistance) earth wire to earth
      • current is greater than the fuse rating, so the fuse melts
      • the kettle is disconnected from the live supply, so the casing is not live / cannot give a shock
  2. 2.In a student flat, a heater, a kettle and a toaster are all plugged into one extension lead. The lead is plugged into a single wall socket.

    1. (a)Explain why this is a hazard.

      2 marks
      Show the answer

      Answer: The appliances are in parallel, so their currents add. The total current in the lead, plug and socket is larger than they are designed for (overloading), so they overheat and could start a fire.

      Marking points

      • the currents add up, so the total current is too large (overloading)
      • the lead / plug / socket overheats and could start a fire
    2. (b)The heater's cable has cracked insulation. Explain why this is dangerous.

      2 marks
      Show the answer

      Answer: A live conductor may be exposed, and touching it could give an electric shock. The live and neutral conductors could also touch, causing a short circuit: a large current that could overheat the cable and start a fire.

      Marking points

      • an exposed live conductor could give an electric shock if touched
      • live and neutral could touch: a short circuit / large current / fire
    3. (c)State why it is dangerous to use a hairdryer with wet hands.

      2 marks
      Show the answer

      Answer: Impure water conducts electricity, so a current can pass through the person to earth, giving an electric shock.

      Marking points

      • (impure) water conducts electricity
      • a current can pass through the person to earth / electric shock
  3. 3.The lighting circuit of a house is protected by a trip switch in the consumer unit. Twelve 100 W lamps on the circuit can all be on at the same time. The mains supply is 230 V.

    1. (a)Describe how the trip switch protects the circuit.

      2 marks
      Show the answer

      Answer: When the current becomes larger than the trip switch's setting, the switch opens automatically and breaks the circuit.

      Marking points

      • when the current is greater than its setting / too large
      • it opens / switches off automatically, breaking the circuit
    2. (b)Give one advantage of a trip switch compared with a fuse.

      1 mark
      Show the answer

      Answer: It can be reset once the fault is fixed, instead of being replaced (it also acts faster).

      Marking points

      • it can be reset (not replaced) / it acts faster
    3. (c)Calculate the current when all twelve lamps are on. Choose a suitable trip-switch setting from 3 A, 6 A, 16 A and 32 A.

      3 marks
      Show the answer

      Answer: Total power = 12 × 100 = 1200 W. I = P ÷ V = 1200 ÷ 230 = 5.2 A. Setting: 6 A, the smallest one above 5.2 A.

      Marking points

      • total power = 1200 W
      • I = 1200 ÷ 230 = 5.2 A
      • 6 A (the smallest setting above 5.2 A)
    4. (d)Explain why each light switch must be connected in the live wire.

      2 marks
      Show the answer

      Answer: Switching off then disconnects the lamp from the live wire and its high p.d. So the lamp holder is not live, and there is no shock risk from it while changing a bulb.

      Marking points

      • switching off disconnects the lamp from the live wire / high p.d.
      • so the lamp holder is not live (no shock when changing a bulb)
  4. 4.A hairdryer is double-insulated. Its cable has only two wires, live and neutral. Its power is 1.6 kW and it is used on a 230 V supply.

    1. (a)Explain why the hairdryer does not need an earth wire.

      2 marks
      Show the answer

      Answer: Its outer casing is made of an insulator (plastic), so it does not conduct. Even if a live wire inside came loose, the casing could not become live.

      Marking points

      • the outer casing is non-conducting / made of an insulator
      • so the casing cannot become live (even if a live wire inside comes loose)
    2. (b)Calculate the normal current in the hairdryer.

      2 marks
      Show the answer

      Answer: I = P ÷ V = 1600 ÷ 230 = 7.0 A

      Marking points

      • I = P ÷ V or 1600 ÷ 230
      • 7.0 A (accept 6.96 A)
    3. (c)Fuses rated 3 A, 5 A, 10 A and 13 A are available. State which fuse should be fitted.

      1 mark
      Show the answer

      Answer: 10 A, the smallest rating above 7.0 A.

      Marking points

      • 10 A
    4. (d)The hairdryer has no earth wire. State what its fuse still protects.

      2 marks
      Show the answer

      Answer: The circuit and the cable (cabling): if live touches neutral, the large current melts the fuse before the cable overheats.

      Marking points

      • the circuit
      • the cable / cabling (from overheating)

Quick check

6 questions

  1. 1.In which wire should the switch of a mains appliance be connected?
  2. 2.A 920 W appliance is used on a 230 V supply. Which fuse should it have?
  3. 3.What happens inside a fuse when the current becomes too large?
  4. 4.Why is the metal casing of a washing machine connected to the earth wire?
  5. 5.Which of these is an example of overloading?
  6. 6.Inside a double-insulated hairdryer, which has no earth wire, the live wire touches the neutral wire. What protects the cable from overheating?