Four scenes, one cable
Each scene follows the same three-core cable. The live core brings the alternating p.d. from the supply, the neutral core completes the circuit at close to 0 V, and the earth core sits at 0 V, joined to any metal case. Every core carries the letter L, N or E as well as its colour, so you never have to rely on colour alone. The mains value comes from the course you pick: 230 V at 50 Hz for GCSE and IGCSE, 220 V at 50 Hz for Pakistan and India, and 120 V at 60 Hz for the USA. These are the commonly quoted figures. India's official nominal value is 230 V, and the real p.d. at a socket varies a little.
Wiring the plug
The plug is the fused UK type, seen from behind with its clear cover lifted off. Drag each core to a terminal, choose how much insulation to strip, and decide whether the strands are twisted tight. Then tighten the cable grip on the outer sheath and clip in the fuse. Press Check and every mistake is listed with its consequence: copper clamped under plastic can overheat, a stray strand can bridge two terminals, and an earth core screwed to the live terminal would make a metal case live. Swapping live and neutral is subtler. The appliance still runs, but its own switch then sits on the neutral side, so its insides stay live after it is switched off.
Making a fault
A metal kettle is plugged in and its live core wears through where the cable enters. With an earth wire, the fault current takes the easy path to earth, over a hundred amps in this model, and the fuse melts within a fraction of a second. Without one, nothing extra flows. The fuse stays whole, the kettle may carry on working, and its case sits at the mains p.d. until something, or someone, gives the current a path to earth. A double-insulated hairdryer shows the other solution: a case that cannot conduct. Finally, a fuse wrongly placed in the neutral melts during a short circuit but leaves the kettle joined to the live supply.
Choosing a fuse
Pick an appliance and the sim works out its normal current:
The right fuse is the smallest standard rating above that current. Too small, and it melts the moment you switch on. Too big, and an overload that the cable cannot handle may not melt it, so the cable overheats instead. A current scale marks the normal current, the cable's safe limit, the fuse rating and the fault current, so you can see why the gap matters. Hide the current in a lesson link and students must calculate it first.
Protecting a home
The last scene is a consumer unit feeding two circuits in parallel. Switch on a kettle and a heater together and the sockets circuit is overloaded, so its breaker trips. Swap to fuses to compare: a breaker can be reset, while a melted fuse must be replaced. A short circuit trips it almost at once. Damp leaking a few hundredths of an amp to earth is far too small for any fuse, but the residual-current device notices that the live and neutral currents no longer match and switches everything off.
What your course expects
AQA names the three wires, their colours and their p.d.s, but not fuses, breakers, RCDs or plug wiring, which are labelled as extras. Cambridge IGCSE makes fuses, trip switches, earthing and double insulation Core. The Punjab Physics 10 book covers household circuits and safety measures in Chapter 16. Mains electricity can kill, so leave real wiring to a qualified electrician.