Punjab Board Class 9 Physics · Physical quantities and measurements
Micrometer screw gauge
Section 1.5
A micrometer screw gauge measures small lengths, such as wire diameters, to 0.01 mm: L.C. = pitch ÷ circular divisions = 0.5 mm ÷ 50. Reading = main scale reading + (circular scale reading × L.C.). Subtract the zero error if the circular zero is below the horizontal line; add it if above.
Vernier Callipers stop at 0.1 mm. The diameter of an electric wire or the thickness of a plastic sheet needs a finer tool. A micrometer screw gauge measures lengths from 0.01 mm up to about 2.5 cm, with a least count of 0.01 mm. It works because a fine screw turns a big, easily seen rotation of the thimble into a tiny forward movement of the spindle.
Part
Its job
Frame
U-shaped body that holds the other parts rigidly
Anvil
Fixed face that the object rests against
Spindle
Moving face, driven forward or back by the screw
Sleeve
Carries the main scale (0.5 mm marks) and the horizontal line
Thimble
Turns the screw; its bevelled edge carries the circular scale of 50 divisions
Ratchet
Slips with a click once the spindle grips, so the object is never squeezed too hard
Pitch and least count
The pitch is the distance the spindle moves in one complete turn of the thimble. On the usual school gauge it is 0.5 mm, the spacing of the marks on the sleeve. One circular division is a fiftieth of a turn, so
L.C.=no. of divisions on the circular scalepitch=500.5mm=0.01mm
Some gauges have 1 mm marks and 100 circular divisions instead. Their least count is still 0.01 mm.
Taking a reading
Turn the thimble until the spindle almost touches the object, then turn the ratchet until it clicks.
Main scale reading: the last mark on the sleeve left uncovered by the thimble's edge. Whole millimetres are on one side of the horizontal line and half millimetres on the other, so check for a half mark.
Circular scale reading: the thimble division lying on the horizontal line.
Close the empty jaws with the ratchet and look at the zero of the circular scale.
On the horizontal line: no zero error.
Below the line: the gauge already shows a small reading, so it reads more than the true thickness. If the zero is n divisions below the line, zero error =n×0.01mm. Subtract it.
Above the line: the gauge reads less than the true thickness. If division k is on the line, zero error =(50−k)×0.01mm. Add it.
Worked numerical: a ball bearing and a wire
(a) Closed, a gauge has its circular zero 2 divisions below the horizontal line. On a bicycle ball bearing, the main scale reading is 4.5 mm and division 32 is on the line. Find the diameter.
Zero error=2×0.01mm=0.02mm(subtract)Observed reading=4.5mm+(32×0.01mm)=4.82mmDiameter=4.82mm−0.02mm=4.80mm
(b) Another gauge, closed, has division 46 on the line with its zero above it. On a copper wire the main scale reads 0.5 mm and division 12 is on the line.
Zero error=(50−46)×0.01mm=0.04mm(add)Diameter=0.5mm+(12×0.01mm)+0.04mm=0.66mm
Using the simulation
In the simulation above, a Steel ball bearing is already gripped. The Main scale reading card shows 7.5 mm (a half mark shows below the line), the Circular scale reading card shows 44, and the Observed reading is 7.94 mm.
Press Open, then Ratchet. The thimble winds in, and the ratchet clicks as the spindle meets the ball.
Under Display, choose the 1 mm · 100 instrument. The same ball now reads 7 mm + 94 × 0.01 mm = 7.94 mm. Switch back to 0.5 mm · 50.
Under Zero error, choose Zero below the line. The observed reading rises to 7.98 mm, and the Corrected reading card shows 7.94 mm (7.98 − 0.04). With Zero above the line, the gauge reads 7.91 mm and 0.03 mm is added.
Pick Nothing (check the zero) from Between the jaws and press Ratchet. With the zero above the line, division 47 sits on the horizontal line, and the working gives (50 − 47) × 0.01 mm = 0.03 mm.
Set Mode to Practice. Press Zero check to read the closed jaws, then Measure to put the object back. Type the corrected reading and press Check.
Common mistakes
✕Missing a half-millimetre mark on the sleeve. If a half mark shows after the last whole millimetre, add 0.5 mm to the main scale reading.
✕Counting a half mark that is still hidden under the thimble. Only marks the thimble edge has uncovered count.
✕Multiplying the circular scale reading by 0.1 mm. Each circular division is 0.01 mm, so 36 divisions add 0.36 mm.
✕Correcting the zero error the wrong way. Zero below the horizontal line: the gauge reads too much, so subtract. Zero above the line: it reads too little, so add.
✕For a zero above the line, using the division on the line as the zero error. Count the divisions from the line up to the zero: (50 − k) × 0.01 mm (a counting rule beyond the book, which just says to add the zero error).
✕Turning the thimble itself to close the jaws tightly, instead of the ratchet. The object gets squeezed and the reading comes out too small.
Exam-style questions
Original questions written in the style of Punjab board exams. Try each one before you reveal the answer.
1.The spindle of a micrometer screw gauge moves forward by 2.0 mm when the thimble is given four complete turns. The circular scale on the thimble has 50 divisions.
(a)What is meant by the pitch of a screw gauge?
1 mark
Show the answerHide the answer
Answer: The distance the spindle moves forward or backward in one complete rotation of the thimble.
Marking points
Distance moved by the spindle in one complete turn of the thimble
(b)Find the pitch of this screw gauge.
1 mark
Show the answerHide the answer
Answer: Pitch = 2.0 mm ÷ 4 = 0.5 mm.
Marking points
2.0 ÷ 4 = 0.5 mm
(c)Calculate its least count.
2 marks
Show the answerHide the answer
Answer: L.C. = pitch ÷ no. of divisions on the circular scale = 0.5 mm ÷ 50 = 0.01 mm.
Marking points
L.C. = pitch ÷ no. of circular divisions
0.5 ÷ 50 = 0.01 mm
2.A student uses a screw gauge (least count 0.01 mm) to measure the diameter of a knitting needle. With the jaws closed, the zero of the circular scale is 3 divisions below the horizontal line.
(a)Calculate the zero error and state whether it is added to or subtracted from the observed reading.
2 marks
Show the answerHide the answer
Answer: Zero error = 3 × 0.01 mm = 0.03 mm. The zero is below the line, so the gauge reads too much and the zero error is subtracted.
Marking points
3 × 0.01 = 0.03 mm
Subtracted (zero below the line reads too much)
(b)On the needle, the main scale reading is 2.5 mm and the 19th circular division is on the horizontal line. Find the observed reading.
2 marks
Show the answerHide the answer
Answer: Observed reading = 2.5 mm + (19 × 0.01 mm) = 2.5 + 0.19 = 2.69 mm.
Marking points
2.5 + 19 × 0.01
2.69 mm
(c)Find the true diameter of the needle.
1 mark
Show the answerHide the answer
Answer: True diameter = 2.69 mm − 0.03 mm = 2.66 mm.
Marking points
2.69 − 0.03 = 2.66 mm
3.Another screw gauge has a pitch of 0.5 mm and 50 circular divisions. With its jaws closed, the 48th circular division is on the horizontal line and the zero of the circular scale is above the line.
(a)Does this gauge read more or less than the true thickness? Give a reason.
2 marks
Show the answerHide the answer
Answer: Less. The circular zero has turned past the horizontal line (it is above it), so the gauge shows a reading below zero when closed and every reading is too small.
Marking points
Reads less (too small)
Zero has gone past / above the horizontal line
(b)Calculate the zero error.
2 marks
Show the answerHide the answer
Answer: Zero error = (50 − 48) × 0.01 mm = 0.02 mm, which is added to each reading.
Marking points
(50 − 48) × 0.01
0.02 mm
(c)The gauge is closed on a glass slide. The last mark showing on the sleeve is the 1.5 mm mark and the 7th circular division is on the line. Find the true thickness of the slide.
2 marks
Show the answerHide the answer
Answer: Observed reading = 1.5 mm + (7 × 0.01 mm) = 1.57 mm. True thickness = 1.57 mm + 0.02 mm = 1.59 mm.
Marking points
Observed reading 1.57 mm
1.57 + 0.02 = 1.59 mm
4.Answer these short questions about the micrometer screw gauge.
(a)State the purpose of the ratchet.
1 mark
Show the answerHide the answer
Answer: It slips with a click once the spindle grips the object, so the object is not over-tightened and every reading is taken with the same gentle pressure.
Marking points
Prevents over-tightening (clicks/slips when the object is gripped)
(b)Explain why a screw gauge, not Vernier Callipers, is used to measure the diameter of a thin wire.
2 marks
Show the answerHide the answer
Answer: A screw gauge has a least count of 0.01 mm, ten times smaller than the 0.1 mm of Vernier Callipers. A thin wire is only a fraction of a millimetre thick, so the screw gauge measures it much more precisely.
Marking points
Least count 0.01 mm against 0.1 mm
Wire diameter is very small, so the screw gauge is more precise