Aim
To measure how current varies with the p.d. across three components in turn, in both directions, and to use the graphs to decide which of them are ohmic. The components are a fixed resistor, a silicon diode and a 12 V filament lamp.
Equipment
- an adjustable d.c. power supply, here 0–12 V in steps of 0.1 V (or a fixed supply with a variable resistor in series)
- a fixed resistor (24 Ω in the lab)
- a filament lamp rated at 12 V, 0.5 A, in a holder
- a silicon diode and a protective resistor (470 Ω in the lab)
- a digital ammeter and a digital voltmeter
- connecting leads
The circuit
The supply, the ammeter and the component under test are all in series, so the ammeter measures the current through the component. The voltmeter is connected in parallel with the component alone, so it reads the p.d. across that component only.
The diode always has its protective resistor in series. Once a diode conducts, its current climbs very quickly for a tiny rise in p.d., and without the resistor it could be destroyed. Keep the voltmeter across the diode alone, not across the diode and the resistor together.
To get negative readings, swap the two leads at the supply. The current then passes through the component the opposite way, and both meters show a minus sign.
Variables
| Type | Variable |
|---|---|
| Independent | Potential difference across the component, changed with the supply (or a variable resistor) |
| Dependent | Current through the component |
| Control | For the fixed resistor, its temperature, kept steady with small currents and by switching off between readings |
Method
- Connect the circuit, starting with the fixed resistor. Before switching on, check that both meters read zero.
- Set a low p.d. and switch on. Once the readings settle, write down the p.d. and the current, and switch off again.
- Increase the supply setting step by step, for example 1 V at a time, up to 12 V. At each setting, take three pairs of readings and work out the mean current.
- Swap the leads at the supply and repeat the same settings. Record these p.d.s and currents as negative values.
- Replace the resistor with the lamp and repeat steps 2 to 4. Stay within the lamp's rating.
- Replace the lamp with the diode and its protective resistor. Take extra readings at low settings, where the diode starts to conduct.
Risk assessment
| Hazard | Risk | Control |
|---|---|---|
| The lamp's glass and filament become very hot | Burns | Do not touch the lamp while it is on, and let it cool before removing it |
| A resistor carrying a large current warms up | Burns, and readings that drift | Use a resistor with a high enough power rating (the lab's 24 Ω resistor takes 6 W at 12 V), keep currents small and switch off between readings |
| A diode connected without a series resistor | The diode overheats and fails | Always include the protective resistor in series with the diode |
The three graphs
Plot current on the vertical axis and p.d. on the horizontal axis, with the origin in the middle so the negative readings fit.
Fixed resistor. The points lie on one straight line through the origin, and the line carries straight on into the negative quadrant. Current is directly proportional to p.d., which means the resistance is the same at every point. A component like this, at a constant temperature, is an ohmic conductor. The lab finds the resistance from the gradient: .
Filament lamp. The graph curves, growing less steep as the p.d. rises. A bigger current heats the thin tungsten filament, and the hotter filament has a higher resistance, so the current rises by less and less for each volt added. Reversing the p.d. heats the filament just as much, so the curve for negative p.d.s is the positive curve rotated half a turn about the origin: an S shape. In the lab's model, V ÷ I rises from about 6 Ω at 1 V to 24 Ω at 12 V. The lamp is not ohmic.
Diode. In reverse, the current is far too small for the ammeter to show: the diode's resistance is very high, so current flows through it in one direction only. Forwards, almost nothing flows until the p.d. across the diode reaches roughly half a volt. Beyond that the current shoots up while the p.d. barely changes. In the lab's model, a straight line through the steep part meets the p.d. axis near 0.66 V. Neither AQA nor Cambridge fixes a value, but silicon diodes typically switch on at around 0.6 to 0.7 V. The diode is not ohmic.
Resistance at a point
At any point on an I–V graph, the resistance is the p.d. divided by the current at that point:
Only for a straight line through the origin does this equal one divided by the gradient. On a curve, the slope of a tangent tells you how fast the current changes, not the resistance. A reading where the current shows zero gives no value of R: the resistance is too large to measure.
Evaluation
Temperature of the resistor. A real resistor left on warms up, and its line would start to bend. The lab's resistor never changes temperature.
Settling time. After each change, the lamp's filament takes a moment to reach its new temperature, so wait until the meter readings stop changing.
Small readings. At 1 V the resistor passes only about 0.04 A, so the ammeter's last digit is a larger share of the reading: the percentage uncertainty is biggest at the smallest p.d.s.
Spacing the diode's readings. The diode's current changes over a few tenths of a volt, so readings 1 V apart would miss the bend. Take several close together there.
Zero errors. A meter that does not read zero before you start shifts every reading by the same amount. Check both meters first.
What your course asks for
AQA, GCSE Physics 4.2.1.4. Required practical activity 4, for both tiers, measures the I–V characteristics of a resistor kept at constant temperature, a filament lamp and a diode (it is also in AQA Combined Science, with a different number). You need to recall , know that a lamp's resistance rises as its filament gets hotter and that a diode lets current through in one direction only, and use graphs to decide whether a component is linear or non-linear. AQA gives no value for the diode's switch-on p.d.
Cambridge IGCSE (0625), 4.2.4. Core statements 1 and 2 ask you to recall and use and to describe how to work out a resistance from voltmeter and ammeter readings. Sketching the current–voltage graphs of a constant resistor, a filament lamp and a diode, and explaining their shapes, is Supplement statement 4. Cambridge has no list of required practicals, but circuits in which you measure current and p.d. are one of the listed contexts for its practical papers.
Exam-style questions
1. Explain why a resistor is connected in series with the diode in this practical. (2 marks)
2. A lamp passes 0.17 A when the p.d. across it is 1.0 V, and 0.50 A when the p.d. is 12.0 V. Calculate its resistance at each p.d. and explain the difference. (4 marks)
3. Describe how the student can take readings with negative values of p.d. (1 mark)
4. For a fixed resistor, V ÷ I comes out at 24 Ω for every reading from −12 V to +12 V. State what this shows about the resistor. (2 marks)
5. Suggest why the student takes more readings for the diode at low power supply settings than at high ones. (1 mark)
6. A student finds the resistance of the lamp at 6 V by drawing a tangent to the curve and taking one divided by its gradient. Explain why this is wrong. (2 marks)